Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 240
Filter
1.
Rev. méd. Chile ; 150(11): 1422-1430, nov. 2022. tab, graf
Article in Spanish | LILACS | ID: biblio-1442047

ABSTRACT

BACKGROUND: Transcatheter aortic-valve implantation (TAVI) was introduced in 2002 and the first implants in our country were performed in 2010. AIM: To review the TAVI experience in our hospital, considering the technology improvements and gained experience throughout this period. MATERIAL AND METHODS: All patients undergoing TAVI in our center were included. Results and complications were adjudicated according to the Valve Academic Research Consortium-2 (VARC-2) criteria. Patients were divided in 3 groups, according to procedural year: Period 1: 2010-2015 (n = 35); Period 2: 2016-2018 (n = 35); Period 3: 2019-2021 (n = 41). Mortality up to one year after the procedure was recorded. RESULTS: Between 2010 and 2021, 111 TAVI procedures were performed. The mean age of patients was 82 years and 47% were women. Risk scores for in-hospital mortality were STS 6.7%, EUROSCORE II 8.0% and ACC/STS TAVR Score 4.9%. The trans-femoral route was used in 88% and a balloon-expandable valve was chosen in 82% of patients. A successful implant was achieved in 96%, with an in-hospital mortality of 1.8%. Mortality at 30 days and 1-year were 2.7 and 9.0%, respectively. During period 3, 100% of implants were successful, with no in-hospital mortality, less vascular complications (p < 0.01), less stroke (p = 0.04), less severe paravalvular leak (p = 0.01) and significantly lower rate of acute complications (p < 0.01). CONCLUSIONS: TAVI achieves excellent results. With greater experience and better available technologies, these results are even more favorable.


Subject(s)
Humans , Male , Female , Aged, 80 and over , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis/adverse effects , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Risk Factors , Treatment Outcome
2.
Braz. J. Anesth. (Impr.) ; 72(5): 629-636, Sept.-Oct. 2022. tab, graf
Article in English | LILACS | ID: biblio-1420601

ABSTRACT

Abstract Background and objectives We aimed to investigate the effects of two different anesthetic techniques in our patients who underwent transcatheter aortic valve implantation (TAVI). Methods In this study, 303 patients who underwent TAVI procedure with a diagnosis of severe aortic stenosis between January 1, 2012 and December 31, 2018 were retrospectively evaluated. The patients were divided according to the type of anesthesia given during each procedure as; general anesthesia (GA), local anesthesia (LA). Results LA was preferred in 245 (80.8%) of 303 patients who underwent TAVI, while GA was preferred in 58 patients (19.1%). Median ages ​​of our patients who received LA and GA were 83 and 84, respectively. The procedure and anesthesia durations of the patients in the GA group were longer than the LA group (p< 0.00001, p< 0.00001, respectively). Demographic and pre-operative clinical data were similar in comparison between two groups (p> 0.05) except for peripheral artery disease. Hypertension was the most common comorbidity in both groups. While the number of inotrope use was significantly higher in patients who received GA (p< 0.00001), no significant differences were found between LA and GA patients in terms of major complications and mortality (p> 0.05). Intensive care and hospital stays were significantly shorter in the LA group (p= 0.001, p= 0.023, respectively). Conclusion The anesthetic technique of TAVI procedure did not have a significant effect on outcomes including; complications, mortality and success of the procedure. LA provides shorter duration of procedure and hospital stay.


Subject(s)
Humans , Aortic Valve Stenosis/surgery , Retrospective Studies , Risk Factors , Anesthetics , Postoperative Complications/etiology , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Anesthesia, General , Anesthesia, Local
4.
Rev. méd. Chile ; 150(2): 183-189, feb. 2022. tab
Article in Spanish | LILACS | ID: biblio-1389642

ABSTRACT

COVID-19 pandemic generated multiple challenges for the health system. Cardiovascular disease is associated with a worse prognosis of infections. Moreover, most hospital resources and operative rooms were destined to patients with COVID-19 infection, deferring the treatment of most valvular patients requiring surgery. We report seven patients with symptomatic severe aortic stenosis who underwent transcatheter aortic valve implantation (TAVI) with conscious sedation and early discharge. No patient required intensive care unit admission or mechanical ventilation. After a 90-day follow-up, there were no complications or unplanned readmissions.


Subject(s)
Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Transcatheter Aortic Valve Replacement/adverse effects , COVID-19 , Patient Discharge , Risk Factors , Conscious Sedation/adverse effects , Treatment Outcome , Pandemics
5.
Journal of Central South University(Medical Sciences) ; (12): 309-318, 2022.
Article in English | WPRIM | ID: wpr-928972

ABSTRACT

OBJECTIVES@#Type 2 diabetes (T2DM) is a common comorbidity in patients with degenerative aortic stenosis (AS).As a key item of the American Society of Thoracic Surgeons (STS) score, it has a vital impact on the clinical prognosis of traditional thoracic surgery. T2DM has an adverse effect on the morbidity and mortality of cardiovascular diseases. At the same time, studies have shown that T2DM are associated with myocardial hypertrophy and remodeling, decreased left ventricular function, and worsening heart failure symptoms in the AS patients. Transcatheter aortic valve replacement (TAVR) as an interventional method to replace the aortic valve has better safety for middle and high risk patients in surgery, but the impact of T2DM on the clinical outcome of TAVR in AS patients is not clear.By analyzing the clinical and image characteristics of patients with AS and T2DM who received TAVR treatment, so as to explore the effect of T2DM on the perioperative complications and prognosis of TAVR.@*METHODS@#A total of 100 consecutive patients with severe AS, who underwent TAVR treatment and were followed up for more than 1 month, were selectedin the Second Xiangya Hospital of Central South University from January 2016 to December 2020.Among them, 5 patients who were treated with TAVR due to simple severe aortic regurgitation were not included, therefore a total of 95 patients with severe aortic stenosis were enrolled in this study.The age of the patients was (72.7±4.8) years old, and there were 58 males (61.1%), and the patients with moderate or above aortic regurgitation had 30 cases (31.6%). The patients were divided into a diabetic group and a non-diabetic group according to whether they were combined with T2DM.There was no statistical difference in age, gender, body mass index (BMI), STS score, and New York Heart Association (NYHA) cardiac function classification between the 2 groups (all P>0.05). The primary end point was defined as a composite event consisting of all-cause death and stroke one month after surgery, and the secondary end point was defined as TAVR-related complications immediately after surgery and one month after surgery.The preoperative clinical data, cardiac ultrasound data, CT data, postoperative medication and the incidence of each endpoint event were compared between the 2 groups.The predictive model of adverse events was constructed by single factor and multivariate logistic regression.@*RESULTS@#Compared with the non-diabetic group, the diabetic group had high blood pressure and chronic renal insufficiency.There was no significant difference in preoperative ultrasound echocardiography between the 2 groups. Preoperative CT evaluation found that the anatomical structure of the aortic root in the diabetic group was smaller than that in the non-diabetic group, and there was no significant difference in the incidence of bicuspid aortic valve between the 2 groups (all P<0.05). In terms of postoperative medication, the use of statins in the diabetes group was significantly higher than that in the non-diabetic group. In the diabetes group, 6 patients (37.5%) received insulin therapy, and 9 patients (56.3%) received oral medication alone.Univariate logistic regression analysis showed that the all-cause death and stroke compound events was increased in the diabetes group in 30 days after TAVR (OR=6.86; 95% CI: 2.14 to 21.79; P<0.01). Heart disease (OR=2.80; 95% CI: 0.99 to 7.88; P<0.05) and chronic renal insufficiency (OR=3.75; 95% CI: 1.24 to 11.34; P<0.05) were also risk factors for all-cause death and stroke compound events.In a multivariate analysis, after adjusting for age, gender, BMI, comorbidities, N-terminal pro-B type natriuretic peptide (NT-proBNP), total calcification score, ejection fraction, and degree of aortic regurgitation, T2DM was still a risk factor for all-cause death and stroke compound events in 30 days after TAVR (OR=12.68; 95% CI: 1.76 to 91.41; P<0.05).@*CONCLUSIONS@#T2DM is a risk factor for short-term poor prognosis in patients with symptomatic severe AS after TAVR treatment. T2DM should play an important role in the future construction of the TAVR surgical risk assessment system, but the conclusions still need to be further verified by long-term follow-up of large-scale clinical studies.


Subject(s)
Aged , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Diabetes Mellitus, Type 2/complications , Renal Insufficiency, Chronic/complications , Risk Factors , Severity of Illness Index , Stroke , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome , United States
6.
Chinese Journal of Cardiology ; (12): 137-141, 2022.
Article in Chinese | WPRIM | ID: wpr-935117

ABSTRACT

Objective: To evaluate the safety and efficacy of transcatheter aortic valve implantation (TAVI) with the novel Prizvalve® system in treating severe aortic stenosis. Methods: This is a single-center, prospective, single-arm, observational study. A total of 11 patients with severe aortic stenosis with high risk or inappropriate for conventional surgical aortic valve replacement (SAVR) were included, and TAVI was achieved with the Prizvalve® system between March 2021 and May 2021 in West China Hospital. Transthoracic echocardiography (TTE) was performed immediately after prosthesis implantation to evaluate mean transaortic gradient and maximal transaortic velocity. The device success rate was calculated, which was defined as (1) the device being delivered via the access, deployed, implanted and withdrawn, (2) mean transaortic gradient<20 mmHg (1 mmHg=0.133 kPa) or a maximal transaortic velocity<3 m/s post TAVI, and without severe aortic regurgitation or paravalvular leak post TAVI. TTE was performed at 30 days after the surgery, and all-cause mortality as well as the major cardiovascular adverse events (including acute myocardial infarction, disabling hemorrhagic or ischemic stroke) up to 30 days post TAVI were analyzed. Results: The age of 11 included patients were (78.1±6.3) years, with 8 males. A total of 10 patients were with NYHA functional class Ⅲ or Ⅳ. Devices were delivered via the access, deployed, implanted and withdrawn successfully in all patients. Post-implant mean transaortic gradient was (7.55±4.08) mmHg and maximal transaortic velocity was (1.78±0.44) m/s, and both decreased significantly as compared to baseline levels (both P<0.05). No severe aortic regurgitation or paravalvular leak was observed post TAVI. Device success was achieved in all the 11 patients. No patient died or experienced major cardiovascular adverse events up to 30 days post TAVI. Mean transaortic gradient was (9.45±5.07) mmHg and maximal transaortic velocity was (2.05±0.42) m/s at 30 days post TAVI, which were similar as the values measured immediately post TAVI (both P>0.05). Conclusions: TAVI with the Prizvalve® system is a feasible and relatively safe procedure for patients with severe aortic stenosis and at high risk or inappropriate for SAVR. Further clinical studies could be launched to obtain more clinical experience with Prizvalve® system.


Subject(s)
Aged , Aged, 80 and over , Humans , Male , Aortic Valve , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation , Prospective Studies , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
7.
Chinese Journal of Cardiology ; (12): 132-136, 2022.
Article in Chinese | WPRIM | ID: wpr-935116

ABSTRACT

Objective: To investigate whether atrial fibrillation (AF) before transcatheter aortic valve implantation (TAVI) will affect the prognosis of patients post TAVI. Methods: This is a single center retrospective study. A total of 115 patients with severe aortic stenosis (AS) who were admitted to General Hospital of Northern Theater Command from May 2016 to November 2020 and successfully received TAVI treatment were included. According to absence or accompaniment of AF pre-TAVI, they were divided into AF group (21 cases) and non-AF group (94 cases). The patients were followed up for postoperative antithrombotic treatment and the occurrence of the net adverse clinical and cerebrovascular events (NACCE) at 12 months post TAVI, including cardiogenic death, readmission to hospital for heart failure, nonfatal myocardial infarction, ischemic stroke and severe bleeding (BARC levels 3-5). Univariate logistic regression was used to analyze the related factors of NACCE. Results: Among the 115 selected patients, age was (73.8±6.9) years, there were 63 males. And 21 cases (18.2%) were diagnosed as AFbefore TAVI. In terms of postoperative antithrombotic therapy, 48.9% (46/94) of the patients in the non-AF group received monotherapy and 47.9% (45/94) received dual antiplatelet therapy. In the AF group, 47.6% (10/21) received anticoagulants and 33.3% (7/21) received dual antiplatelet therapy. The proportion of patients in the AF group taking non-vitamin K antagonist oral anticoagulants (NOAC) was higher than that in the non-AF group (38.1% (8/21) vs. 2.1% (2/94), P<0.001). Patients in both groups were followed up to 12 months after TAVI. During the 12 months follow-up, the incidence of NACCE after TAVI was 14.3% (3/21) in the AF group, which was numerically higher than that in the non-AF group (6.4% (6/94)), but the difference was not statistically significant (P=0.441). The incidence of severe bleeding was significantly higher in the AF group than in the non-AF group (9.5% (2/21) vs. 0, P=0.032). Univariate logistic regression analysis showed that hypertension was associated with the risk of NACCE (OR=8.308, P=0.050), while AF was not associated with the risk of NACCE (P=0.235). Conclusion: The incidence of severe bleeding after TAVI is higher in patients with AF than in patients without AF prior TAVI, and there is a trend of increased risk of NACCE post TAVI in AF patients.


Subject(s)
Aged , Aged, 80 and over , Humans , Male , Anticoagulants , Aortic Valve , Aortic Valve Stenosis/surgery , Atrial Fibrillation/drug therapy , Follow-Up Studies , Retrospective Studies , Risk Factors , Transcatheter Aortic Valve Replacement , Treatment Outcome
8.
Chinese Journal of Cardiology ; (12): 698-704, 2022.
Article in Chinese | WPRIM | ID: wpr-940909

ABSTRACT

Objectives: To explore the efficacy and safety of emergency transcatheter aortic valve replacement (TAVR). Methods: Data of patients who underwent emergency TAVR in eight centers, namely Fuwai Hospital, Wuhan Asia Heart Hospital, Xijing Hospital, Union Hospital Affiliated to Tongji Medical College of Huazhong University of Science and Technology, Guangdong Provincial People's Hospital, Zhongshan Hospital Affiliated to Fudan University, the First Affiliated Hospital of Zhengzhou University, the Second Xiangya Hospital of Central South University, between May 2017 and December 2020 were retrospectively analyzed. The use of mechanical circulatory support system (MCS) and the results of laboratory tests (N-terminal B-type natriuretic peptide (NT-proBNP)) and echocardiography (mean aortic valve cross valve pressure difference and left ventricular ejection fraction) before and after operation were collected. The primary endpoint was all-cause death, and the secondary endpoints were stroke, major bleeding, major vascular complications, myocardial infarction, permanent pacemaker implantation, and acute renal injury. Device success was caculated, which refered to absence of procedural mortality and correct positioning of a single prosthetic heart valve into the proper anatomical location and intended performance of the prosthetic heart valve (mean aortic valve gradient<20 mmHg(1 mmHg=0.133 kPa) or peak velocity<3 m/s, with no moderate or severe prosthetic valve regurgitation). Kaplan-Meier survival curve was used to estimate the survival rate of patients during follow-up. Results: This study included 48 patients. The age was (72.5±8.1) years, and 34 patients were males (70.8%). Device success rate was 91.7% (44/48). The mean aortic valve transvalvular pressure was significantly decreased after operation ((12.3±6.4)mmHg vs. (60.2±23.8)mmHg, P<0.000 1). Left ventricular ejection fraction was significantly increased ((41.5±11.7)% vs. (31.0±11.3)%, P<0.000 1). NT-proBNP significantly decreased (3 492.0 (1 638.8, 7 165.5) ng/L vs. 12 418.5 (6 693.8, 35 000.0) ng/L, P<0.000 1). In-hospital all-cause mortality was 8.3% (4/48). During hospitalization, the rate of stroke was 2.1% (1/48), major bleeding was 6.3% (3/48), major vascular complications was 10.4% (5/48), myocardial infarction was 4.2% (2/48), permanent pacemaker implantation was 6.3% (3/48), and the rate of acute renal injury was 12.5% (6/48). MCS was used in 20 patients (41.7%). The median follow-up time was 196 days. During the follow-up, one patient died (due to systemic metastasis of pancreatic cancer), two cases suffered new myocardial infarction and one case received permanent pacemaker implantation. The survival rate of 30 days, 1 year and 2 years after the operation were 91.7% (44/48), 89.6% (43/48), 89.6% (43/48), respectively. Conclusion: Emergency TAVR may be a safe and effective treatment for patients with severe decompensated aortic valve stenosis.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Acute Kidney Injury , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis , Myocardial Infarction/surgery , Retrospective Studies , Risk Factors , Stroke , Stroke Volume , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome , Ventricular Function, Left
9.
Chinese Journal of Cardiology ; (12): 563-569, 2022.
Article in Chinese | WPRIM | ID: wpr-940889

ABSTRACT

Objective: To summarize the single center experience of transcatheter aortic valve replacement (TAVR) with a simplified operative protocol. Methods: Consecutive patients who underwent transfemoral TAVR (TF-TAVR) from July 2020 to December 2020 in Fuwai Hospital were retrospectively analyzed. We compared the baseline characteristic, procedure information, 30-day follow-up outcomes of the patients who underwent TF-TAVR without the simplified operative protocol (routine group) or with the simplified operative protocol (simplified protocol group). Results: 93 patients were collected, 42 patients belonging to routine group, 51 patients belonging to simplified protocol group. In simplified protocol group, there were 51 patients planned to use ultrasound-guided femoral access puncture, procedure was successful in all 51 patients (100%). There were 49 patients planned to use the radial artery as the secondary access, procedure was successful in 45 patients (92%). There were 48 patients planned to use the strategy of avoidance of urinary catheter, this strategy was achieved in 35 patients (73%). There were 12 patients planned to use the left ventricular guidewire to pace, procedure was successful in 11 patients (92%). There were no differences in baseline characteristics, major clinical endpoints and 30-day follow-up outcomes between the two groups. Meanwhile, the procedure time ((62.5±17.9)min vs. (78.3±16.7)min, P<0.001), operation room time ((133.7±25.1)min vs. (159.2±42.6)min, P<0.001), X-ray exposure time ((17.2±6.5)min vs. (20.2±7.7)min, P=0.027) were significantly shorten in simplified protocol group compared with the routine group. Conclusion: Our study results indicate that the simplified operative protocol of TF-TAVR is as effective and safe as the routine operative protocol, meanwhile using the simplified operative protocol can significantly increase the operative efficiency of TF-TAVR.


Subject(s)
Humans , Aortic Valve , Aortic Valve Stenosis/surgery , Femoral Artery/surgery , Retrospective Studies , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
10.
Chinese Journal of Cardiology ; (12): 1193-1200, 2022.
Article in Chinese | WPRIM | ID: wpr-969726

ABSTRACT

Objective: To compare the impact of bicuspid aortic valve (BAV) or tricuspid aortic valve (TAV) on hemodynamics and left ventricular reverse remodeling after transcatheter aortic valve replacement (TAVR). Methods: We retrospectively analyzed the clinical data of patients who underwent TAVR in our hospital from January 2019 to March 2021. Patients were divided into BAV group and TAV group according to aortic contrast-enhanced CT. Each patient was followed up by N-terminal pro B-type natriuretic peptide (NT-proBNP) and echocardiography at four time points, namely before TAVR, 24 hours, 1 month and 6 months after TAVR. Echocardiographic data, including mean pressure gradient (MPG), aortic valve area (AVA), left ventricular ejection fraction (LVEF), left ventricle mass (LVM) and LV mass index (LVMi) were evaluated. Results: A total of 41 patients were included. The age was (75.0±8.6) years, and male patients accounted for 53.7%. There were 19 BAV patients and 22 TAV patients in this cohort. All patients undergoing TAVR using a self-expandable prosthesis Venus-A valve. MPG was (54.16±21.22) mmHg(1 mmHg=0.133 kPa) before TAVR, (21.11±9.04) mmHg at 24 hours after TAVR, (18.84±7.37) mmHg at 1 month after TAVR, (17.68±6.04) mmHg at 6 months after TAVR in BAV group. LVEF was (50.42±13.30)% before TAVR, (53.84±10.59)% at 24 hours after TAVR, (55.68±8.71)% at 1 month after TAVR and (57.42±7.78)% at 6 months after TAVR in BAV group. MPG and LVEF substantially improved at each time point after operation, and the difference was statistically significant (all P<0.05) in BAV group. MPG in TAV group improved at each time point after operation, and the difference was statistically significant (all P<0.05). LVMi was (164.13±49.53), (156.37±39.11), (146.65±38.84) and (134.13±39.83) g/m2 at the 4 time points and the value was significantly reduced at 1 and 6 months post TAVR compared to preoperative level(both P<0.05). LVEF in the TAV group remained unchanged at 24 hours after operation, but it was improved at 1 month and 6 months after operation, and the difference was statistically significant (all P<0.05). LVMi in TAV group substantially improved at each time point after operation, and the difference was statistically significant (all P<0.05). NT-proBNP in both two groups improved after operation, at 1 month and 6 months after operation, and the difference was statistically significant (all P<0.05). MPG in TAV group improved better than in BAV group during the postoperative follow-up (24 hours after TAVR: (11.68±5.09) mmHg vs. (21.11±9.04) mmHg, P<0.001, 1 month after TAVR: (10.82±3.71) mmHg vs. (18.84±7.37) mmHg, P<0.001, 6 months after TAVR: (12.36±4.42) mmHg vs. (17.68±6.04) mmHg, P=0.003). There was no significant difference in NT-proBNP between BAV group and TAV group at each time point after operation (all P>0.05). There was no significant difference in paravalvular regurgitation and second prosthesis implantation between the two groups (all P>0.05). Conclusions: AS patients with BAV or TAV experience hemodynamic improvement and obvious left ventricular reverse remodeling after TAVR, and the therapeutic effects of TAVR are similar between BAV and TAV AS patients in the short-term post TAVR.


Subject(s)
Humans , Male , Aged , Aged, 80 and over , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Bicuspid Aortic Valve Disease/surgery , Aortic Valve Stenosis/surgery , Retrospective Studies , Stroke Volume , Heart Valve Diseases , Ventricular Function, Left , Treatment Outcome , Ventricular Remodeling , Hemodynamics
11.
Rev. chil. cardiol ; 40(3): 241-244, dic. 2021. ilus
Article in Spanish | LILACS | ID: biblio-1388102

ABSTRACT

Resumen: La válvula aórtica es una estructura más compleja de lo que hasta hace poco se estimaba y en la actualidad se considera a esta una estructura más de la "Raíz Aórtica", cuyos componentes se describen en el presente "Artículo Especial". Lo anterior ha alcanzado mayor importancia con el desarrollo de los procedimientos quirúrgicos que permiten preservar la válvula aórtica en la insuficiencia aórtica, pero, muy especialmente, para el tratamiento percutáneo de la estenosis aórtica, de la cual se reconocen, a su vez, tres formas principales, que también se describen en el presente artículo.


Abstract: The aortic valve is a more complex structure than has been estimated until recently and is now considered to be just another structure of the "Aortic Root", the components of which are described in this "Special Feature". This has become more important with the development of surgical procedures that allow preservation of the aortic valve in aortic insufficiency, but especially for the percutaneous treatment of aortic stenosis, of which three main forms are recognized, which are also described in this article.


Subject(s)
Humans , Adult , Aortic Valve/anatomy & histology , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/methods
12.
Rev. bras. cir. cardiovasc ; 36(6): 796-801, Nov.-Dec. 2021. tab, graf
Article in English | LILACS | ID: biblio-1351669

ABSTRACT

Abstract Introduction: The Glasgow prognostic score (GPS) reflects host systemic inflammatory response and has been reported to be significant as a prognostic indicator in cancer-bearing patients. The aim of this study was to evaluate the predictive value of GPS in outcomes of patients with severe aortic stenosis who were treated with transcatheter aortic valve implantation (TAVI). Methods: The study population consisted of 79 patients who underwent TAVI due to severe aortic stenosis between January 2018 and March 2019 in our clinic. Echocardiographic and laboratory data were recorded before the procedure and GPS was scored as 0, 1, or 2, based on serum albumin and C-reactive protein levels. European System for Cardiac Operative Risk Evaluation II scoring system was used for risk stratification. The primary endpoints of the study were postoperative in-hospital mortality, hospitalization due to cardiac causes, or mortality within a year. Results: The 79 patients were classified into two groups according to outcomes. Fifteen patients (19%) reached the primary endpoints at one year of follow-up. Compared to the patients who did not reach the endpoints, these 15 patients were not different in terms of age, preoperative mean gradient, and ejection fraction (P>0.05 for all). GPS was the only laboratory parameter with statistically significant difference between the groups (P=0.008) and multivariate analysis showed that GPS was independent predictor of primary endpoints (P=0.012, odds ratio 4.51, 95% confidence interval 1.39-14.60). Conclusion: GPS is an easy, noninvasive laboratory test which may be used as a predictive biomarker for outcomes in patients undergoing TAVI.


Subject(s)
Humans , Aortic Valve Stenosis/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/surgery , Prognosis , Time Factors , Biomarkers , Risk Factors , Treatment Outcome
13.
Int. j. cardiovasc. sci. (Impr.) ; 34(5,supl.1): 34-40, Nov. 2021. graf, tab
Article in English | LILACS, CONASS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1346335

ABSTRACT

BACKGROUND: The treatment for symptomatic severe aortic stenosis (AS) is the correction of valve stenosis by surgical valve replacement and more recently by transcatheter aortic valve implant (TAVI). However, in some high risk surgical patients, TAVI is not possible for technical or clinical reasons or due to the unavailability of the endoprosthesis. OBJECTIVE: The aim of this study was to evaluate a mid-term follow-up of symptomatic severe AS patients who are not eligible for TAVI trials, as well as to identify the clinical features of these patients. METHODS: This was an observational, retrospective study conducted with 475 symptomatic severe AS patients, evaluated by the Heart Team between 2000 and 2017. Inclusion criterias were: patients considered not to be eligible for TAVI. The Shapiro-Wilk test was applied to evaluate normality. Non-paired t and Mann-Whitney tests were applied for continuous variables, while the chi-squared and Fischer exact tests were applied for categorical variables, with a level of significance of p<0,05. RESULTS: The heart team evaluated 475 patients: 25 (5.26%) died before any intervention could be proposed; 326 (68.3%) were submitted to TAVI, so the study population consisted of 124 patients not eligible for TAVI. Of these, 31 (25%) underwent surgery and 93 (75%) remained in clinical treatment. In a mean 56 months- follow-up the mortality in clinical group was 46.2%. In the surgical group the mortality was 23.9% (in-hospital 12.9% and late mortality 11% in a mean 47.4 months follow-up). The patients that died presented a significantly lower left ventricle ejection fraction (LVEF), a smaller valve area, and a larger end-systolic diameter of the LV. CONCLUSION: The mortality of the clinical group's patients was significantly higher than the surgical mortality (46.2% vs. 12.9%; p=0.021). The patients of the clinical group were older, weighed less, and had a higher incidence of renal failure and a higher STS score.


Subject(s)
Humans , Male , Female , Aged , Aged, 80 and over , Aortic Valve Stenosis/surgery , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/therapy , Retrospective Studies
14.
Arq. bras. cardiol ; 117(5): 1018-1027, nov. 2021. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1350022

ABSTRACT

Resumo Fundamento: A proteína C-reativa (PCR) é um biomarcador de inflamação preditor de eventos adversos em procedimentos cardiovasculares. Na avaliação do implante da válvula aórtica transcateter (transcatheter aortic valve implantation, TAVI) em relação ao prognóstico de longo prazo ainda é incipiente. Objetivo: Avaliar a PCR como marcador prognóstico no primeiro ano pós-TAVI na estenose aórtica (EAo). Métodos: A PCR foi avaliada na primeira semana do peroperatório numa coorte de casos retrospectiva com EAo. Correlacionou-se a PCR pré- e pós-TAVI com a mortalidade e foram pesquisados fatores preditores de mortalidade em 1 ano. Realizada regressão de Cox multivariada para identificar os preditores independentes de óbito em 1 ano. Resultados: Estudados 130 pacientes submetidos a TAVI, com mediana de idade de 83 anos, sendo 49% deles do sexo feminino. A PCR pré-TAVI elevada (> 0,5 mg/dL) ocorreu em 34,5% dos casos. O pico de PCR foi 7,0 (5,3-12,1) mg/dL no quarto dia. A mortalidade em 1 ano foi 14,5% (n = 19), sendo maior nos grupos com PCR pré-TAVI elevada (68,8% vs 29,1%; p = 0,004) e pico de PCR ≥ 10,0 mg/dL (64,7% vs 30,8%; p = 0,009). Os fatores preditores independentes de mortalidade foram insuficiência renal aguda (IRA) [razão de risco (RR) = 7,43; intervalo de confiança de 95% (IC95%), 2,1-24,7; p = 0,001], PCR pré-TAVI elevada [RR = 4,15; IC95%, 1,3-12,9; p=0,01] e hemotransfusão volumosa [HR = 4,68; 1,3-16,7; p = 0,02]. Conclusões: A PCR pré-TAVI elevada mostrou-se fator preditor independente de mortalidade no primeiro ano, assim como a ocorrência de IRA e hemotransfusões volumosas.


Abstract Background: C-reactive protein (CRP) is an inflammation biomarker that can be a predictor of adverse events in cardiovascular procedures. Its use in the assessment of long-term prognosis of transcatheter aortic valve implantation (TAVI) is still incipient. Objective: To evaluate CRP as a prognostic marker in the first year after TAVI in aortic stenosis (AoS). Methods: CRP was assessed on the first postoperative week in a retrospective cohort of patients with AoS. Pre- and post- CRP levels were correlated with mortality, and predictors of 1-year mortality were investigated. Multivariate Cox regression was performed to identify independent factors of 1-year mortality. Results: This study evaluated 130 patients who underwent TAVI, with median age of 83 years, and 49% of women. High pre-TAVI CRP (> 0.5 mg/dL) was observed in 34.5% of the cases. Peak CRP was 7.0 (5.3-12.1) mg/dL no quarto dia. The rate of 1-year mortality was 14.5% (n = 19), being greater in the groups with high pre-TAVI CRP (68.8% vs 29.1%; p = 0,004) and with peak CRP ≥ 10.0 mg/dL (64.7% vs 30.8%; p = 0,009). Independent predictors of mortality were acute renal failure (ARF) (hazard ratio [HR] = 7.43; 95% confidence interval [95%CI], 2.1-24.7; p = 0,001), high pre-TAVI CRP (HR 4.15; 95%CI, 1.3-12.9; p = 0.01), and large blood transfusion [HR 4,68; 1,3-16,7; p = 0.02]. Conclusions: High pre-TAVI CRP showed to be an independent predictor of 1-year mortality, as well as the presence of ARF and large blood transfusions.


Subject(s)
Humans , Male , Female , Aged, 80 and over , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/metabolism , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/surgery , Prognosis , C-Reactive Protein/analysis , Retrospective Studies , Risk Factors , Treatment Outcome
17.
Int. j. cardiovasc. sci. (Impr.) ; 34(5,supl.1): 78-86, Nov. 2021. tab, graf
Article in English | LILACS | ID: biblio-1346350

ABSTRACT

Abstract Background There is no consensus among tools for assessing frailty. Objective To evaluate the prevalence of frailty according to different tools in patients referred for elective valve cardiac surgery. Methods This is a cross-sectional study. All patients were ≥ 18 years of age, clinically stable. The following patients were excluded: those unable to perform the tests because of physical, cognitive, or neurological limitations; those requiring non elective/emergency procedures or hemodynamic instability. During the preoperative cardiology visit, frailty was assessed by the Short Physical Performance Battery (SPPB), the Frailty Deficit Index (FDI), handgrip strength, and gait speed 3m. For the entire analysis, the statistical significance was set at 5%. Results Our cohort consisted of 258 subjects. From the total cohort, 201 were ≤ 70 years of age (77.9%), the predominant etiology according to rheumatic disease (50.7% vs 8.8%; p=0.000) with double mitral lesion (24.9% vs 0%; p=0.000). Frailty was present in 32.9% according SPPB, 29.1% with reduced muscular strength. and 8.9% with FDI. Handgrip strength was weaker in elderly patients (26.7 vs 23.6; p=0.051) and gait speed was lower in the younger group, in which 36% were considered frail (36% vs 14%; p=0.002). Variables associated with frailty were age ≥ 70 years, female gender, aortic stenosis, and regurgitation. Conclusion Frailty in adult patients who will have elective heart valve surgery is present even in the younger groups, although the older group with comorbidities are more frail. Frailty was more clearly shown by the SPPB than by the FDI and handgrip tests.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Aortic Valve Stenosis/surgery , Frail Elderly , Frailty/diagnosis , Heart Valves/surgery , Rheumatic Diseases , Prevalence , Cross-Sectional Studies , Preoperative Period , Walking Speed , Frailty/epidemiology , Gait Analysis , Cardiac Surgical Procedures
19.
Rev. Assoc. Med. Bras. (1992) ; 67(9): 1311-1316, Sept. 2021. tab
Article in English | LILACS | ID: biblio-1351458

ABSTRACT

SUMMARY INTRODUCTION: According to recent studies, the rate of atrioventricular block requiring permanent pacing in patients following transcatheter aortic valve implantation varied between 5.7% and 42.5%. Fragmented QRS is a useful marker of myocardial scar and can predict adverse cardiac events. In this study, we examined association between f ragmented QRS and postprocedural rhythm disturbances and the need for permanent pacing in patients who underwent transcatheter aortic valve implantation. OBJECTIVE: In this study, we examined association between fragmented QRS and postprocedural rhythm disturbances and the need for permanent pacing in patients who underwent transcatheter aortic valve implantation' sentence is enough for it. METHODS: We retrospectively analyzed standard 12-lead electrocardiographic recordings of 124 consecutive patients in whom a CoreValve prosthesis was implanted. We examined 12-lead electrocardiogram before and after procedure along with one- and six-month follow-up. We documented QRS fragmentation and postprocedural rhythm disturbances. RESULTS: There was a significant increase in the frequency of left bundle branch block, (21.1 versus 0%, p<0.05) and the incidence of atrioventricular blocks requiring permanent pacing (21.1 versus 0%, p<0.05) following transcatheter aortic valve implantation in patients whose preprocedural electrocardiogram recordings revealed fragmented QRS compared to those without fragmented QRS. Based our collected data, the presence of QRS fragmentation in anterior derivations was the only independent factor associated with postprocedural rhythm disturbances (B-value 0.217; OR 0.805; 95%CI 0.136-4.78; p=0.004). CONCLUSION: Our data showed an increased risk for the development of new-onset left bundle branch block and atrioventricular blocks following transcatheter aortic valve implantation in patients whose baseline electrocardiogram recordings demonstrated QRS fragmentation.


Subject(s)
Humans , Aortic Valve Stenosis/surgery , Pacemaker, Artificial , Heart Valve Prosthesis/adverse effects , Transcatheter Aortic Valve Replacement/adverse effects , Cardiac Pacing, Artificial , Retrospective Studies , Risk Factors , Treatment Outcome , Electrocardiography
20.
Arq. bras. cardiol ; 117(3): 512-517, Sept. 2021. tab
Article in English, Portuguese | LILACS | ID: biblio-1339177

ABSTRACT

Resumo Fundamentos A síndrome de Heyde é a associação de estenose aórtica importante com episódio de sangramento gastrointestinal por lesões angiodisplásicas. Pouco é conhecido sobre os fatores associados a novos sangramentos e desfechos em longo prazo. Além disso, a maioria dos dados é restrita a relatos de casos e pequenas séries. Objetivo Avaliar o perfil clínico, laboratorial e ecocardiográfico de pacientes com síndrome de Heyde submetidos a intervenção valvar ou tratamento medicamentoso. Métodos Coorte prospectiva de 24 pacientes consecutivos entre 2005 e 2018. Foram avaliados dados clínicos, laboratoriais, ecocardiográficos e relacionados à intervenção valvar e a desfechos após o diagnóstico. Valor de p<0,05 foi considerado estatisticamente significante. Resultados Metade dos 24 pacientes apresentou sangramento com necessidade de transfusão sanguínea na admissão. Angiodisplasias foram encontradas mais frequentemente no cólon ascendente (62%). Intervenção valvar (cirúrgica ou transcateter) foi realizada em 70,8% dos pacientes, e 29,2% foram mantidos em tratamento clínico. Novos episódios de sangramento ocorreram em 25% dos casos, e não houve diferença entre os grupos clínico e intervenção (28,6 vs. 23,5%, p=1,00; respectivamente). A mortalidade no seguimento de 2 e 5 anos foi de 16% e 25%, sem diferença entre os grupos (log-rank p = 0,185 e 0,737, respectivamente). Conclusões Pacientes com síndrome de Heyde tiveram alta taxa de sangramento com necessidade de transfusão sanguínea na admissão, sugerindo ser uma doença grave e com risco elevado de mortalidade. Não encontramos diferenças entre os grupos submetidos ao tratamento clínico e à intervenção valvar em relação a taxas de ressangramento e mortalidade tardia.


Abstract Background Heyde's syndrome is the association of severe aortic stenosis with episodes of gastrointestinal bleeding due to angiodysplastic lesion. Little is known about the factors associated with new episodes of bleeding and long-term outcomes. Furthermore, most data are restricted to case reports and small case series. Objective To assess the clinical, laboratory and echocardiography profile of patients with Heyde's syndrome who underwent valve intervention or drug therapy. Methods Prospective cohort of 24 consecutive patients from 2005 to 2018. Clinical, laboratory and echocardiography data were assessed, as well as those related to valve intervention and outcomes after diagnosis. A P <0.05 was used to indicate statistical significance. Results Half of the 24 patients presented with bleeding requiring blood transfusion on admission. Angiodysplasias were more frequently found in the ascending colon (62%). Valve intervention (surgical or transcatheter) was performed in 70.8% of the patients, and 29.2% remained on drug therapy. News episodes of bleeding occurred in 25% of the cases, and there was no difference between clinical and intervention groups (28.6 vs 23.5%, p = 1.00; respectively). Mortality at 2-year and 5-year was 16% and 25%, with no difference between the groups (log-rank p = 0.185 and 0.737, respectively). Conclusions Patients with Heyde's syndrome had a high rate of bleeding requiring blood transfusion on admission, suggesting that it is a severe disease with high mortality risk. No difference was found between clinical and intervention group regarding the rate of rebleeding and late mortality.


Subject(s)
Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Angiodysplasia/complications , Angiodysplasia/therapy , Prospective Studies , Follow-Up Studies , Gastrointestinal Hemorrhage/etiology , Gastrointestinal Hemorrhage/therapy
SELECTION OF CITATIONS
SEARCH DETAIL